LTER network Toolik Field Station MBLhome page

Weather at Toolik

Toolik Weather Graphs

Arctic LTER Weather Stations

Toolik Webcam

Animated Gif of yesterday's Webcam

Arctic LTER Inhouse login

Arctic LTER Database

Arctic LTER Database

Conditions of Use

The re-use of scientific data has the potential to greatly increase communication, collaboration and synthesis within and among disciplines, and thus is fostered, supported and encouraged. Permission to use this dataset is granted to the Data User free of charge subject to the following terms:

1) Acceptable use. Use of the dataset will be restricted to academic, research, educational, government, recreational, or other not-for-profit professional purposes. The Data User is permitted to produce and distribute derived works from this dataset provided that they are released under the same license terms as those accompanying this Data Set. Any other uses for the Data Set or its derived products will require explicit permission from the dataset owner.
2 ) Redistribution. The data are provided for use by the Data User. The metadata and this license must accompany all copies made and be available to all users of this Data Set. The Data User will not redistribute the original Data Set beyond this collaboration sphere.
3 ) Citation. It is considered a matter of professional ethics to acknowledge the work of other scientists. Thus, the Data User will properly cite the Data Set in any publications or in the metadata of any derived data products that were produced using the Data Set. Citation should take the following general form: Creator, Year of Data Publication, Title of Dataset, Publisher, Dataset identifier. For example:

Shaver, G. 1989. Above ground biomass in acidic tussock tundra experimental site, 1989, Arctic LTER, Toolik, Alaska. Arctic LTER, Marine Biological Lab, Woods Hole, Ma 02543. 1989gsttbm http://ecosystems.mbl.edu/arc/terrest/biomass/index.shtml 

4 ) Acknowledgement. The Data User should acknowledge any institutional support or specific funding awards referenced in the metadata accompanying this dataset in any publications where the Data Set contributed significantly to its content. Acknowledgements should identify the supporting party, the party that received the support, and any identifying information such as grant numbers. For example:

Data sets were provided by the Arctic LTER. This material is based upon work supported by the National Science Foundation under Grants #DEB-981022, 9211775, 8702328; #OPP-9911278, 9911681, 9732281, 9615411, 9615563, 9615942, 9615949, 9400722, 9415411, 9318529; #BSR 9019055, 8806635, 8507493.

5 ) Notification. The Data User will notify the Data Set Contact when any derivative work or publication based on or derived from the Data Set is distributed. The Data User will provide the data contact with two reprints of any publications resulting from use of the Data Set and will provide copies, or on-line access to, any derived digital products. Notification will include an explanation of how the Data Set was used to produce the derived work.
6 ) Collaboration. The Data Set has been released in the spirit of open scientific collaboration. Data Users are thus strongly encouraged to consider consultation, collaboration and/or co-authorship with the Data Set Creator.

By accepting this Data Set, the Data User agrees to abide by the terms of this agreement. The Data Owner shall have the right to terminate this agreement immediately by written notice upon the Data User's breach of, or non-compliance with, any of its terms. The Data User may be held responsible for any misuse that is caused or encouraged by the Data User's failure to abide by the terms of this agreement.

Disclaimer

While substantial efforts are made to ensure the accuracy of data and documentation contained in this Data Set, complete accuracy of data and metadata cannot be guaranteed. All data and metadata are made available "as is". The Data User holds all parties involved in the production or distribution of the Data Set harmless for damages resulting from its use or interpretation.

Dataset URLs:METADATA: HTML, Rich Text, XML(EML compliant)
DATA: Comma Delimited, Excel file with Metadata and data
Dataset ID:2007dlMATd.03
Dataset Title:Daily weather and soil temperature data from the Arctic LTER Moist Acidic Tussock Experimental plots for 2007, Toolik Filed Station, North Slope, Alaska.
Investigator 1: 
First Name:Gus
Last Name:Shaver
Organization:Marine Biological Lab
Address line 2:The Ecosystems Center
Address line 3:7 MBL St
City:Woods Hole
State:MA
Zip Code:02543
Country:USA
Investigator 2: 
First Name:Jim
Last Name:Laundre
Organization:Marine Biological Lab
Address line 2:The Ecosystems Center
Address line 3:7 MBL St
City:Woods Hole
State:MA
Zip Code:02543
Country:USA
Associate Investigators:
Keywords:weather, air temperature, relative humidity, soil temperature, radiation, wind
Abstract:Daily weather and soil temperature data from the Toolik Tussock Experimental plots. In 1990 a Campbell CR21X data logger was installed in block 2 of the Toolik LTER experimental tussock plots. The plots are located on a hillside near Toolik Lake (68 38' N, 149 36'W). Sensors were placed in a control, fertilized, greenhouse, greenhouse fertilized, shade house and shade house fertilized plots.
For questions about the Metadata and data contact the Investigators.
For information about this web site contact:
Arctic LTER Information Manager
The Ecosystems Center
Marine Biological Lab
7 MBL St
Woods Hole, MA 02543
Phone (508) 289 7496
Email: arc_im@mbl.edu
Online URL: http://ecosystems.mbl.edu/ARC/
DATA FILE INFORMATION:
Data File URL http://metacat.lternet.edu/das/dataAccessServlet?docid=knb-lter-arc.10028&urlTail=weather/tu/data/2007dlMATd.csv
Data File Name 2007dlMATd.dat
Beginning Date 1/1/2007
End Date 12/31/2007
Number of Data Records 365
Other Files to Reference
Availability Status
Quality Control Information
Maintenance Description
Log of Changes: Version 1: DATA FILE ENTERED BY: J.Laundre
Version 2: Upadte LTERNET Data Access server proxy link for Excel and comma delimited data files. Changed from knb to das in url.
Version 3: Metadata updated to newer form (with sites sheet). Units updated to current standards. CH April 2013.
 
RESEARCH LOCATION:                  
Location Name LTER Moist Acidic Tussock Tundra Select Site or enter New One Select Site or enter New One Select Site or enter New One Select Site or enter New One Select Site or enter New One Select Site or enter New One Select Site or enter New One  
Geographic Description Toolik Lake Field Station (68 38' N, 149 36'W), LTER moist acidic tussock site on hill south of Toolik Lake, North Slope of Alaska. Enter Description Enter Description Enter Description Enter Description Enter Description Enter Description Enter Description  
Location Bounding Box                  
West Bounding Coordinate                  
East Bounding Coordinate                  
North Bounding Coordinate                  
South Bounding Coordinate                  
OR if single point location                  
Latitude 68.624 In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees  
Longitude -149.607 In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees In Decimal Degrees  
Elevation 746 In Meters In Meters In Meters In Meters In Meters In Meters In Meters  
Link to Google Map View on Google Map                
                   
 
TAXONOMIC COVERAGE:
Organisms studied
 
Methods:A data logger, in the LTER acidic experimental plots (moist acidic tundra site - MAT) (block 2), is used to monitor weather and soil temperatures.
Sensors in the control plot include: global solar radiation, photosynthetic active radiation, unfrozen precipitation, air temperature, relative humidity, wind speed, and wind direction at 3 meters. Additional seasons in greenhouses and shade houses plots measure air temperature, relative humidity and photosynthetic active radiation during the growing season. These sensors are read every minute and averaged or totaled every hour.
Two profiles of soil temperature are measured per treatment plot with copper/constantin thermocouple wires (TC) installed at depths of 10, 20, and 40 cm in inter-tussock areas. The following label codes are used: CT = control, GH = greenhouses, SH = shade houses, F = fertilized, GF= greenhouse fertilized, SF = shade house fertilized, plus a 1 or a 2 for the profile number. All soil sensors are read every 15 minutes and averaged every 3 hours.
Hourly, three hourly and daily summaries are in files yyDLTUH.DAT, yyDLTUO.DAT, and yDLMATD.DAT respectively, where yy is the year in which the data are collected. The original data are in file yyDLTDAT.ZIP which is archived at The Marine Biological Lab, Woods Hole, MA.

NOTES:

The covers on greenhouses and shade houses are removed every fall and reinstalled every spring.

Only unfrozen precipitation is reported.

Soil temperatures are problematic since frost heaving of the probes caused depth of measurements to change.

In January, February and December When the air temperature is < -30 degrees the soil temperatures will show a slight rise due to increased error of the reference temperature used for the theromcouples.

For the global solar radiation and photosynthetic active radiation sensors no attempt is made to correct for frost or snow on the sensors during the winter months. Therefore winter radiation data should be view as suspect and used only qualitatively.

The CS500 Temperture/RH sensor does not read below -40 C. All temperture values below -38.5 were deleted.
The Greenhouse and Sahde house PAR sensors were not functioning summer 2007.

Missing values are indicated by #N/A

-----------------------------------------------------------------------------------------------------------------------------------------------
Sensor Description

Following are brief descriptions of the sensors used at the weather monitoring station. Included with each description is a list of stations using the sensor and the number of sensors at that site. Company addresses follow the list.
---------------------------------------------------------------------------------------------------------------------------------------------
PYRANOMETER:
Li-Cor, Pyranometer: Model LI-200SA- Sensor measures global solar radiation (sun plus sky). Specs: Sensitivity - 80mA per 1000 Watts m-2. Absolute error max ±5% but typically ±3
QUANTUM:
Li-Cor, Quantum. Model LI-190SB. Quantum measure photosynthetically active radiation (PAR) in ?mol s-1 m-2. Specs: range 400-700nm wavelength. Sensitivity 8mA/1000 ?mol s-1 m-2. Relative error less then ±10% for plant canopies or less then ±5% for growth chambers. Toolik.
RELATIVE HUMIDITY/TEMPERATURE:
Campbell Scientific, CS500 Temperature and Relative Humidity Probe. Uses PRT for temperature measurement; capacitive RH chip for RH. Accuracy is ±3% over 10-90% RH; ±6% over 90-100% RH. Manufactured by Vaisala, Inc.
WIND DIRECTION:
MET-ONE, (supplied by Campbell Scientific) Wind direction use a light weight, air foil vane and a potentiometer to produce an output that varies proportional with wind direction. Specs: Minimum Wind speed to get accurate reading = 1.0 mph. Accuracy ±5° Temperature range -50 to 70°C.
WIND SPEED:
MET-ONE, (supplied by Campbell Scientific) Wind speed sensor Model 014A. Sensor uses a 3-cup anemometer assembly and simple magnet-read switch assembly to produce a series of contact closures whose frequency is proportional to wind speed. Specs: Operating Range - 0 to 125 mph or 0-60 m/s. Accuracy ±1.5% or 0.25 mph. Working temperature range - -50 to 85°C
RAIN GAUGE:
Texas Electronics, Inc. (supplied by Campbell Scientific) Tipping Bucket Electric Rain Gauge. A complex spun collector funnel with a knife edge that diverts the water to a tipping bucket mechanism. For each tip a magnet causes an electronic pulse that is recorded. Each alternate tip occurs for each 0.01 inch of rainfall. Specs: Accuracy 1% at 2 inches/hr or less. Accurate Temperature Range: 0 - 37°C. Alter wind shield installed around gauge.
THERMOCOUPLES:
Omega Engineering, Copper-Constantan wire. Range -200 to 350 °C. Limits of error: Standard wire 1.0°C or 0.75% above 0°C and 1.0°C or 1.5% below 0°C. Special wire 0.5°C or 0.4%.
List of manufactories and suppliers.
Campbell Scientific, Inc.
81 W. 1800 N.
Logan, Utah 84321-1784
(435)750-1739

Druck Inc.
4 Dunham Drive
New Fairfield, CT 06812
(203)746-0400

Li-Cor
4421 Superior St
P.O. Box 4425
Lincoln, Nebraska 68504
(800)447-3576

Omega Engineering, Inc.
P.O. Box 4047
Stamford, CT 06907-0047
(800)826-6342

Reference Citations: Buck, A.L. 1981 New equations for computing vapor pressure and enhancement factor. Journal of Applied Meteorology 20:1527-1532.

Vapor Press Formula:
If Air Temp > 0 then (CRH 3M/100) * 6.1121 * exp(17.368 * CTEMP 3M/(238.88 + CTEMP 3M))
If Air Temp < 0 then (CRH 3M/100) * 6.1121 * exp(17.966 * CTEMP 3M/(238.88 + CTEMP 3M))
(Buck 1981).

Data Table

Variable Name Variable Description Data Type Units DateTime Format Code Information Missing Value Code
Date Date datetime   DD-MMM-YYYY    
Month Month datetime   mm    
ID Program step that output the data number number     #N/A=Missing or Not Measured
Year Year datetime   yyyy    
Julian Julian Date number number      
RAIN mm Total daily unfrozen rain number millimeter     #N/A=Missing or Not Measured
CT TEMP 3M Daily average air temperature at 3meter number celsius     #N/A=Missing or Not Measured
CT TEMP MAX 3M Maximum temperature at 3 meter number celsius     #N/A=Missing or Not Measured
MAX HOUR CT TEMP 3M Time of air temperature max at 3 meters datetime   hhmm   #N/A=Missing or Not Measured
WS MAX 3M Wind Speed Maximum at 3 meter number meterPerSecond     #N/A=Missing or Not Measured
MAX HOUR WIND SP Time of wind speed Max at 3M datetime   hhmm   #N/A=Missing or Not Measured
CT TEMP MIN 3M Minimum air temperature at 3 meter number celsius     #N/A=Missing or Not Measured
MIN HOUR CT TEMP 3M Time of air temperature min at 3 meter datetime   hhmm   #N/A=Missing or Not Measured
WIND SP 3M Daily average wind speed at 3-meter number meterPerSecond     #N/A=Missing or Not Measured
GH TEMP Daily greenhouse air temperature number celsius     #N/A=Missing or Not Measured
SH TEMP Daily shade house air temperature number celsius     #N/A=Missing or Not Measured
CT Quantum mol/m2/day Control Photosynthetic Active Radiation sensor in number molePerMeterSquaredPerDay     #N/A=Missing or Not Measured
GH Quantum mol/m2/day Greenhouse Photosynthetic Active Radiation sensor number molePerMeterSquaredPerDay     #N/A=Missing or Not Measured
SH Quantum mol/m2/day Shade house Photosynthetic Active Radiation sensor in number molePerMeterSquaredPerDay     #N/A=Missing or Not Measured
Vapor Press Daily average vapor pressure for Control temperature/relative humidity at 3 meters. number millibar     #N/A=Missing or Not Measured
PYR TOTAL J CM2 DAY Daily total joules/cm2 (sum of hourly average PYRANOMETERreadings * .3600 jcm2 * 1000 watt/Kwatt) onlyf from May through September. number joulePerCentimeterSquaredPerDay     #N/A=Missing or Not Measured
Comments Comments about individual datum points. text        
Please contact arc_im@mbl.edu with questions, comments, or for technical assistance regarding this web site.