Acceptance and utilization of PIE-LTER data requires that:
· The Principal Investigator be sent a notice stating reasons for acquiring any data and a description of the publication intentions.
· The Principal Investigator of the data set be sent a copy of the report or manuscript prior to submission and be adequately cited in any resultant publications.
· A copy of any resultant publications should be sent to:
(Principal Investigator)
Ecosystems Center;
Marine Biological Laboratory
Woods Hole, MA 02543
PLUM ISLAND ECOSYSTEM LTER DATABASE
DATA FILE: MON-PR-MBYSI2000.txt
DOCUMENTATION FILE: MON-PR-MBYSI2000.doc
YEAR: 2000
PI: Charles Hopkinson
OTHERS: Hap Garritt
BRIEF DESCRIPTION OF DATA FILE:
15 minute readings of water column temperature, salinity, oxygen, depth, and turbidity in the upper Parker River Estuary at Middle Bridge
KEYWORDS: temperature, oxygen, conductivity, salinity, turbidity, depth, dissolved, saturation, gas, Parker, monitoring
SITE TYPE: Monitoring
RESEARCH LOCATION: MON-PR-Middle Bridge YSI
Parker River, Middle Road Bridge (Thurlow’s Bridge, Byefield, Massachusetts)
Latitude 42o 45’ 31.9”, Longitude 70o 54’ 3.2”
EXPERIMENTAL DESIGN AND METHODS:
Measurements are made using a YSI 6600 water quality sonde with internal datalogging capabilities. YSI Sonde sensors consist of 6562 dissolved oxygen probe (rapid pulse – Clark type,polarographic), 6560 conductivity/temperature probe (thermistor), vented level depth sensor (stainless steel strain gauge) and 6026 wiping turbidity probe(optical, 90o scatter).
NOTES AND COMMENTS:
VARIABLE DESCRIPTION:
|
NAME |
DESCRIPTION |
UNIT |
PRECISION |
|
Date |
Date of sampling |
dd-mmm-yyyy |
1 |
|
Time |
Time of sampling (eastern standard time EST) |
hh:mm:ss |
1 |
|
Station |
Name of sampling station |
|
|
|
Temp |
Temperature of water |
Celsius |
0.01 |
|
SpCond |
Specific conductivity of water |
mS/cm |
0.001 to 0.1 |
|
Salinity |
Salinity of water |
Parts per thousand |
0.01 |
|
DO% |
Percent dissolved oxygen saturation of water |
Percent |
0.1 |
|
DO Conc |
Dissolved oxygen concentration of water |
mg/l |
0.01 |
|
DO Charge |
Dissolved oxygen sensor charge |
Integer |
|
|
Depth |
Water column depth above sonde pressure transducer |
Meter |
0.001 |
|
Turbidity |
Turbidity of water |
Nephelometric turbidity unit |
0.1 |
|
Comments |
Comments about specific data |
|
|
CALCULATIONS:
FOR MORE INFORMATION, CONTACT:
Hap Garritt
OTHER DATA FILES TO REFERENCE:
REFERENCE CITATIONS:
DATA AVAILABILITY STATUS:
Type 2
ARCHIVE INFORMATION:
Date of entry: March 3, 2001
Data entered by: H. Garritt
Comments: