Plum Island Ecosystem LTER Database

http://ecosystems.mbl.edu/PIE

 

 

Acceptance and utilization of PIE-LTER data requires that:

·        The Principal Investigator be sent a notice stating reasons for acquiring any data and a description of the publication intentions.

·        The Principal Investigator of the data set be sent a copy of the report or manuscript prior to submission and be adequately cited in any resultant publications.

·        A copy of any resultant publications should be sent to:

(Principal Investigator)
Ecosystems Center;
Marine Biological Laboratory
Woods Hole, MA 02543

 

 

PLUM ISLAND ECOSYSTEM LTER DATABASE

DATA FILE:                                        MON-PR-MBYSI2002.txt

DOCUMENTATION FILE:                MON-PR-MBYSI2002.doc

YEAR: 2002

PI: Charles Hopkinson

OTHERS: Hap Garritt

BRIEF DESCRIPTION OF DATA FILE:

15 minute readings of water column temperature, salinity, oxygen, depth, and turbidity in the upper Parker River Estuary at Middle Bridge

KEYWORDS: temperature, oxygen, conductivity, salinity, turbidity, depth, dissolved, saturation, gas, Parker, monitoring

SITE TYPE: Monitoring

RESEARCH LOCATION: MON-PR-Middle Bridge YSI

Parker River, Middle Road Bridge (Thurlow’s Bridge, Byefield, Massachusetts)

Latitude 42o 45’ 31.9”,  Longitude 70o 54’ 3.2”

EXPERIMENTAL DESIGN AND METHODS:

Measurements are made using a YSI 6600 water quality sonde with internal datalogging capabilities. YSI Sonde sensors consist of 6562 dissolved oxygen probe (rapid pulse – Clark type,polarographic), 6560 conductivity/temperature probe (thermistor), vented level depth sensor (stainless steel strain gauge) and 6026 wiping turbidity probe(optical, 90o scatter).

NOTES AND COMMENTS:

VARIABLE DESCRIPTION:

NAME

DESCRIPTION

UNIT

PRECISION

Date

Date of sampling

dd-mmm-yyyy

1

Time

Time of sampling (eastern standard time EST)

hh:mm:ss

1

Station

Name of sampling station

 

 

Temp

Temperature of water

Celsius

0.01

SpCond

Specific conductivity of water

mS/cm

0.001 to 0.1

Salinity

Salinity of water

Parts per thousand

0.01

DO%

Percent dissolved oxygen saturation of water

Percent

0.1

DO Conc

Dissolved oxygen concentration of water

mg/l

0.01

DO Charge

Dissolved oxygen sensor charge

Integer

 

Depth

Water column depth above sonde pressure transducer

Meter

0.001

Turbidity

Turbidity of water

Nephelometric turbidity unit

0.1

Comments

Comments about specific data

 

 

CALCULATIONS:

FOR MORE INFORMATION, CONTACT:

Hap Garritt

OTHER DATA FILES TO REFERENCE:

REFERENCE CITATIONS:

DATA AVAILABILITY STATUS:

Type 2

ARCHIVE INFORMATION:

Date of entry: March 19, 2003

Data entered by: H. Garritt

Comments: