ATB Experiment 1 - Cycling of energy input.

This experiment is being conducted to examine the conjecture that living systems differ from inanimate systems, such as fire, in that they maximize entropy production averaged over a characteristic time scale appropriate to the system based on perturbations the system has evolved to cope with. The ability of living systems to average entropy production over time results from their ability to predict future states based on information (in a Shannon context) that is stored in their genome and acquired (learned) via Darwinian evolution and culled by natural selection.

Simply stated, Free energy spawns the creation of information that hastens free energy’s destruction.

In this experiment, two replicate methanotrophic microcosms (MCs) are continuously sparged with methane plus air, while two other replicate MCs are periodically sparged between methane + air and just air. The initial cycle period was 20 days (10 days with CH4 + air and 10 days with just air), was reduced to 4 days, and is currently not being cycled. Hypothesis: The microbial communities will adapt (and evolve) to the periodic energy input such that internal entropy production in cycled MCs will match that in MCs with continuous energy input when integrated over the cycle period.  The major uncertainly and caveat is, how long will it take for the systems to adapt?

Note, current MEP model for the MCs indicates that the cycle treatements are functioning at a MEP state; however, the communitiy cannot allocate metabolic machinery fast enough to perform as well as the control MCs.  See: Vallino, J.J., Algar, C.K., Fernandez Gonzalez, N., Huber, J.A.. (2014) Use of receding horizon optimal control to solve MaxEP-based biogeochemistry problems. In Beyond the Second Law: Entropy Production and Non-Equilibrium Systems, Dewar, R.C., Lineweaver, C., Niven, R. and Regenauer-Lieb, K.,  (eds), Springer, pp 337-359, doi: 10.1007/978-3-642-40154-1_18. (draft version)

Some near real-time gas data from the MCs are given below and electrode data on other pages (see menu bar). These images will be updated every 5 hours (you may need to refresh your browser window to see latest data).  Time zero of this experiment corresponds to 0:00 20 Aug 2010. Energy cycling began on day 210.5 (18 Mar 2011); on 12 Jan 2014, the cycling has been temporarily stopped.

*** As of 23 Jan 2015 11:11 the sampling of the microcosms as ended and will be taken down shortly.  Data will be posted shortly.


Carbon Dioxide Data (last 40 days):

Profile of CO2 production
Image of All CO2 data

Methane Data (last 40 days):

Profile of methane consumption
Image of All CH4 data

Oxygen Data (last 40 days):

Profile of Oxygen consumption
Image of All O2 data

Instrument Deviation Corrections (last 40 days):

Deviations of instruments between calibrations
Image of All Instrument Deviations data

Electrode data (pH, DO and ORP) are here.

Experimental Events:

  1. Experiment Begun (t = 0 set at 00:00:00 20 Aug 2010)
  2. Microcosms (MCs) cross inoculated (t = 3.8 d).
  3. Media added to attain 18 L volume (t = 4.8 d).
  4. New pH and DO probes installed (t=13.8 d)
  5. Porous ceramic gas diffusers installed (t=20.8 d)
  6. Reversed rotation of impellers, same speed: 10 RPM (t=27.5 d)
  7. Chemostat hardware installed, and MCs setup to operate as "circle-o-stats"; MC 1 -> MC 2 -> MC 3 ->MC 4 -> MC 1. Flow rate is set at 10 mL/min.  This will allow cross mixing all of MCs (20:00 21 Sep 10; t = 32.8 d)
  8. High flow ceramic gas diffusers installed, and ORP probes cleaned (18:00 14 Oct 10, t=55.7 d).
  9. Normal chemostat operation started with D = 0.1 d-1, or 1.25 mL min-1 (17:40 21 Oct 10, t=62.7 d). Medium composition: 700 μM KNO3, 70 μM KH2PO4, 100 μM MgSO4, 100 μM CaCl2, 100 μM NaCl, plus trace element solution.
  10. UPS failure, system and gas flow shut down for ~ 24 hrs (11:00 24 Oct 10, t=65.45 d).
  11. DO probes repaired and installed.  Biomas/detritus clumps around probes and sample tubes broken up by general mixing of MCs.  ORP probes cleaned and pH probes calibrated. (12:00 12 Nov 10, t=84.5 d).
  12. System returned to "circle-o-stat" mode (see event 7. above), with a flow rate of 20 mL/min. Feed of medium temporarily turned off. (13:06 21 Dec 2010, t = 123.5 d)
  13. Resuspended particulat matter and cleaned ceramic gas diffusers. (15:00 23 Dec 2010, t = 125.6 d)
  14. Returned to chemostat mode with D = 0.05 d-1, or 0.60 mL min-1 (19:15 30 Dec 2010, t = 132.8 d).
  15. Cleaned ceramic diffusers. (17:40 6 Jan 2011, t = 139.7 d)
  16. Chemostat flow rate increased to D = 0.1 d-1, or 1.25 mL min-1 (15:40 7 Jan 2011, t = 140.7 d)
  17. Cleaned ceramic diffusers. (16:40 13 Jan 2011, t = 146.7 d)
  18. Cleaned ceramic diffusers. (16:30 25 Jan 2011, t = 158.7 d)
  19. Concentration of KNO3 reduced from 700 to 400 μM.  See event 9 above.  (17:45 26 Jan 2011, t = 159.7 d)
  20. Cleaned diffusers and electrodes. (17:30 3 Feb 2011, t = 167.7 d)
  21. Concentration of KNO3 reduced from 400 to 100 μM.  See event 9 above.  (10:30 6 Feb 2011, t = 170.4 d)
  22. Cleaned gas diffusers and electrodes. (17:30 17 Feb 2011, t = 181.7 d)
  23. Concentration of KNO3 reduced from 100 to 50 μM.  See events 9 and 21 above.  (15:00 18 Feb 2011, t = 182.6 d)
  24. Cleaned gas diffusers and cleaned and calibrated electrodes. (17:30 4 Mar 2011, t = 196.7 d)
  25. Feed turned off for 2 days starting at 7:00 12 Mar 2011 (t = 204.3 d).
  26. Gas cycling started for MCs 1 and 4. Air only will be on for 10 days followed by air + methane for 10 days.  This cycling (20 day period) to MCs 1 and 4 only will continue automatically until stopped.  (11:45 18 Mar 2011, t = 210.49 d)
  27. Calibrated and cleaned DO and pH probes, cleaned ORP probes. (17:00 5 Apr 2011, t = 228.71 d)
  28. Calibrated DO, pH, pumps, and gas analyzers (17:00  3 May 2011, t = 256.7 d)
  29. 900 μmoles of KNO3 were added to all MCs (50 μM MC concentration) to confirm for NO3- limitation (14:45 13 May 2011, t = 266.61 d).
  30. Phosphate buffer (10 mM, pH 6.8) was added to all MCs because low pH may be limiting metabolism based on 13 May  KNO3 spike response (14:30 19 May 2011, t = 272.60 d).
  31. Currently microcosms are being sampled every 10 days for nutrients, DNA/RNA, and cell counts (viruses, prokaryotes and eukaryotes), which induces the small spike in gas concentration data (25 Aug 2011, t = 370.00 d).
  32. DO and pH probes recalibrated (17:00 21 Oct 2011, t = 427.71 d)
  33. DO probes reconditioned, pH probes and chemostat pumps calibrated (16:00 10 Jan 2012, t = 508.67 d)
  34. Gas cycling reduced to a 4 day period, 2 days on, 2 days off (15:35 11 Jan 2012, t = 509.65 d)
  35. Computer failure 4:00 10 Mar 2012 (t = 568.17 d). System maintained in CH4+Air mode.  Hardware fixed 9:00 13 Mar 2012 (t = 571.38 d).  One CH4 off cycle missed.
  36. Nine samples being taken over the course of a single methane cycle period (started 6 Aug 2012 13:30, t = 717.56 d, ending 10 Aug 2012 13:30, t = 721.56 d).
  37. Methane cycling on MC's 1 and 4 has been stopped, and they have been returned to continuous methane + air input (12 Jan 2014 15:30, t =1241.65 d).
  38. Drop in MC3 respiration due to biofilm development on ceramic gas diffuser, seen here.  All diffusers were cleaned as well: 18 Jul 2014 (t = 1428.5 d)
  39. Bioreactors placed on batch model (media flow turned off) at 7 Aug 2014 11:00, t = 1448.5 d)
  40. Sampling of the bioreactors has stopped, and are being terminated (23 Jan 2015, t = 1617.47 d)

Experimental Equipment:

Image of all microcosms after cross inoculatingInstrument rack
Image (left) shows the four Bellco Glass 18 L methanotrophic microcosms on 24 Aug 2010 (t = 4.8 d), which have been in continuous operation since 7 Oct 2005. Instrument rack and environmental chamber housing the MCs (image on right) is equipped with MKS mass flow controllers, CAI NDIR methane analyzer, Oxigraf O2 and CO2 laser diode absorption spectrometer, Consort D230 data acquisition system for pH, DO and redox probes, Nafion drier and a computer for monitoring and experimental control via Valco selector valve, ASCO solenoid valves, Weeder Technologies WTDOT digital IO board and Comtrol RocketPort serial card.  Monitoring and control software is written in Intel Fortran (gigidy) and all com is via rs232.

Microcosms are sparged using porous ceramic gas diffusers at 30 psig at a flow rate of 20 sccm controlled by MKS MFCs.  A closed gas sampling loop regulated at a flow rate 240 mL/min by a Hargraves mini pump (B.1F15E4.A12VDC) delivers reactor headspace gas to analyzers.

Source code for control and monitoring is given below, but the program is not very user friendly, nor is there extensive documentation, but they still may be of some use:

Graphics are generated by Tecplot